Empirically Calibrated Hydro-Spatial Physics Engine

Interactive Maneuvering &
Fairway Compression Simulator

Explore the 1:1 scale collision physics of commercial tows and deep-draft yachts transiting the New River. All channel widths, platted property boundaries, seawall offsets, and bend radii are calibrated to the July 2024 Terraquatic Bathymetric Survey (Job No. 24-1868) and City Marine Advisory Board (MAB) / BCPA / USACE GIS Exhibits.

Reach: Little Florida Hairpin Turn | Survey Radius: 170 ft (Apex 107 ft) | USACE / FIND Toe: 82 ft | Scale: 1:1 True Survey Geometry
Seawall / Shore (Brown) Typical 60' Channel (Light Blue) Needed Turning Extension (Yellow) Dock Conflict Zone (Red)
Clear Fairway
How to Read This Simulation (1:1 Scale Survey Exhibit) Calibrated to Terraquatic Survey Job No. 24-1868 (1" = 50') & MAB BCPA/USACE GIS (1" = 60')
1. Brown Boundaries: The physical seawalls and bulkheads surveyed along the water's edge (with dashed red lines showing the upland BCPA platted property line).
2. Light Blue Corridor: The standard 60-foot baseline channel matching Downtown drawbridge fender openings and MAB GIS exhibits.
3. Yellow Extension Wings: The extra turning width required outside the 60-foot channel for this vessel to pivot through the surveyed bend radius.
4. Red Cross-Hatched Area: The Conflict Zone where the vessel's required turning path collides with the permitted dock zone.
Maneuvering & Survey Parameters
Vessel Length (LOA): 210 ft
Vessel Beam (Width): 50 ft
Tidal Current: -1.4 kts (Ebb)
Cumulative Seawall Creep (Both Banks): 8 ft (Surveyed)
Slide to 0 ft where seawalls coincide with BCPA parcel lines, or up to 25+ ft where sistered seawalls/bulkheads extend waterward.
Dock Allocation (Code Section 8-91 / ULDR): 30% per bank (60% Total)
Measurement Baseline:
Real-Time Hydro-Spatial Metrics
BCPA Platted Property Width: 134.0 ft
Seawall Encroachment / Creep: -8.0 ft (Both Banks)
Active Waterway Width: 126.0 ft (Physical Seawall)
Opposing Dock Allocation Loss: -75.6 ft
Remaining Open Water Fairway: 50.4 ft
Surveyed -14' NAVD88 Contour Width: 52.0 ft (0 ft at STA. 108+50)
PIANC Turn Drift Angle: 38.1 deg
Required Turning Swept Path: 192.4 ft
Navigational Margin: -142.0 ft
F.S. 327.44 Compliance

Survey Data Provenance & Primary Source Citation
Hydrodynamic Engineering Standards

The Technical Basis: PIANC & USACE Channel Design Standards

How certified naval architecture formulas, rigid-hull chord-sagitta geometry, and federal navigation guidelines establish the physical boundaries of the New River fairway.

Global Navigation Guideline

PIANC Report No. 121-2014: Swept Path Modeling

PIANC (World Association for Waterborne Transport Infrastructure) Report No. 121-2014 establishes the global engineering standard for harbor channels and restricted fairways.

  • Rigid-Arc Swept Envelope: When a rigid vessel or combined tug-and-barge package navigates a circular bend, its bow and stern swing outward while its midpoint cuts inward. The simulator computes this exact geometric chord-sagitta width using radius of curvature and vessel length.
  • Vertical-Wall Bank Suction (Table 2.3): PIANC mandates a minimum bank clearance of 0.3B (30% of vessel beam) on each bank for vertical sheet-pile or seawall canals. For a 50-foot beam utility barge, safe hydrodynamic clearance requires 15 feet per bank (30 feet total) to prevent hydrodynamic bank suction from pulling the stern into moored yachts.
  • Hydrodynamic Leeway: Outward drift from tidal currents pushes vessels across bend centerlines, requiring calibrated hydrodynamic expansion wings.
PIANC Report No. 121-2014 (§§ 2.1-2.4, Table 2.3)
Federal Hydraulic Engineering

USACE EM 1110-2-1613 & Section 10 Baselines

The U.S. Army Corps of Engineers (USACE) Engineering Manual EM 1110-2-1613 (Hydraulic Design of Deep-Draft Navigation Channels) and Section 10 regulatory policies establish federal baseline clearances.

  • The 25% / 50% Rule of Thumb: In evaluating Department of the Army permits under Section 10 of the Rivers and Harbors Act, USACE regulatory practice limits private dock structures to 25% of waterway width, reserving at least 50% as an open navigation fairway.
  • The River Curve Breakdown: While a 50% fairway operates reliably in straight residential canals, it fails in river curves. In a 100-foot bend, a 50% open channel leaves only 50 feet of water, whereas an infrastructure barge sweeping an arc requires 100 to 112 feet of clear passage.
  • USACE Channel Toe: Federal survey sheets establish fixed bottom toe boundaries (80 to 105 ft on Sheets 8, 10, 13, 14) that define the navigable prism.
USACE EM 1110-2-1613; 33 U.S.C. § 403
Survey Data Provenance

Multi-Baseline Triangulation & Seawall Creep

Navigational risk cannot be measured from a single data source. The simulator cross-references three distinct geographic boundaries calibrated to certified surveys:

  • 1. Platted BCPA Parcel Lines: The legal boundary platted on dry upland deeds. Measuring setbacks solely from this line ignores physical encroachment into the public watercourse.
  • 2. Surveyed Seawall Face: Certified under Terraquatic Job No. 24-1868. Decades of "sistering" (building new bulkheads waterward of decaying walls) have advanced shorelines 8 to 20 feet into the New River.
  • 3. Deep-Water Bathymetric Contour: The -10 ft to -14 ft NAVD88 deep sill. At The Wiggles (STA. 125+15), the deep channel pinches to 38 feet, restricting deep-draft hulls regardless of surface width.
Terraquatic Job No. 24-1868 (July 2024); BCPA GIS
01

Cross-Examine the Hydrographic Data

Primary Data Sources

Every dimension, radius, and station plotted in this simulator originates from certified engineering surveys. Cross-examine the depth soundings on the 24-sheet bathymetric survey, inspect the municipal GIS overlays, or review the legal framework governing riparian dock privileges.

View 24-Sheet Bathymetric Survey Inspect Choke Point Maps Review Waterway Precedent